Welcome to ROS Robot Expansion Board repository
1.17Host computer use
ROSMASTER IMU Host Software · Beginner Tutorial
Applicable system: Windows 10 / 11 (64-bit) | Communication baud rate: 115200 | No internet connection or development environment required
1. Preparation
| Item | Description |
|---|---|
| Computer | Windows 10 / 11, 64-bit, with Microsoft Edge or Google Chrome installed (Edge is built into Win10/11) |
| ROSMASTER driver board / car | Already flashed with the matching firmware |
| USB data cable | Must be a cable capable of data transfer; charge-only cables will not work |
| Software package | ROSMASTER_IMU_x.x.x_Windows_x64.zip |
1.1 Download the Software
Download the host software ROSMASTER_IMU.exe from the provided materials and save it to a local folder

2. Launch the Software
Connect the board to the computer with a USB cable and make sure the 12V power supply is stable.
Keep the board stationary for a few seconds. After the board is powered on, press the reset button and wait for it to complete the startup calibration.

Double-click
ROSMASTER_IMU.exe.

On first use, a usage and disclaimer notice pops up; click "I understand, start using"

After a moment, the maximized software window appears.

3. Connect the Board
Click the [Connect Serial Port] button in the upper-right corner of the window.

The "Select Serial Port" window pops up. Select the port corresponding to the board in the list (usually shown as
USB-SERIAL CH340,CP210x, orCOMx) and click "Connect".

Not sure which port it is? Unplug the USB cable and check the list, then plug it back in; the extra entry that appears is the board.
After a successful connection, you will see:
The status at the top becomes normal (data present);
The receive rate (FPS) is shown in the upper-right corner, usually between 30 and 100;
The 3D model starts to rotate with the board.

✅ If the 3D model moves with the board, the connection is successful.
4. Getting to Know the Main Interface
| Area | Function |
|---|---|
| ① Top bar | Connect/disconnect serial port, battery level, record data, import replay, emergency stop, language and background switching |
| ② Left navigation | Switch between the 6 workbenches |
| ③ Central work area | Content of the current workbench |
| ④ "Help / About" in the lower-left corner | View the version number, runtime requirements, and FAQ |
The 6 workbenches:
| No. | Name | Purpose |
|---|---|---|
| 01 | Overview | 3D attitude + 9-axis data + control; the most commonly used in daily work |
| 02 | Chassis Driving | Control the car's forward/backward movement and steering; single-motor test (corresponding peripherals required) |
| 03 | Sensor Waveforms | Acceleration / angular rate / magnetic field waveforms |
| 04 | Servos and Peripherals | Servos, RGB LED strip, buzzer |
| 05 | Spatial Attitude | Large-screen 3D attitude and compass |
| 06 | Calibration Workbench | Magnetometer calibration and result verification |
5. Common Functions
5.1 View the 3D Attitude
Go to 01 Overview or 05 Spatial Attitude.
Rotate view: hold the left mouse button and drag on the 3D view.
Zoom: scroll the mouse wheel.
Reset view: click "Reset View" to restore the default view.
Zero yaw: click "Zero Yaw" to take the current heading as 0°.
Model direction opposite/inverted relative to the real device: check
R(roll),P(pitch), orY(yaw) under Flip 180°. This only changes the display and does not affect the real data.
5.2 View Sensor Waveforms
Go to 03 Sensor Waveforms:
ACC: acceleration (X / Y / Z)
GYR: angular rate (X / Y / Z)
MAG: magnetic field strength (X / Y / Z)
You can select the time window (3 / 5 / 10 / 20 s); click "Pause Waveform" to freeze the display, and "Clear History" to start over.
5.3 Drive the Car Chassis
⚠️ Safety reminder: before testing, lift the car so the wheels are off the ground, or make sure the surrounding area is clear. If anything unexpected happens, immediately click the red [Emergency Stop] at the top.
Go to 02 Chassis Driving:
① Select the vehicle model (required on first use)
Click [Vehicle Model Configuration].
Click "Read Vehicle Model" to confirm the current model; if it is wrong, select your model from the drop-down list.
Choose "Apply Temporarily" (valid for this session only) or "Save to Device Flash" (permanent), then close the configuration.
② Directional Driving
Hold the direction button with the mouse to drive; release it to stop immediately.
After checking "Enable Keyboard Driving", you can use the keyboard:
W/Sforward/backward,A/Dstrafe left/right,Q/Erotate in place,Spacebrake.The speed can be adjusted with the slider or preset buttons; it is recommended to start at a low speed (10~50 mm/s).
③ Single-Motor PWM Test (troubleshooting wiring)
Switch to "Single-Motor PWM".
Set the percentage and hold the corresponding M1~M4 button; that motor rotates and stops when released.
Only one motor runs at a time.
5.4 Servos / LED Strip / Buzzer
Go to 04 Servos and Peripherals:
PWM servos: drag the slider to control the angle of S1~S4; "Synchronized Linkage" moves all four together.
Bus servos: the movement time can be set (300 / 500 / 1000 / 2000 ms); "Lock/Release" controls the torque, and after release the robotic arm can be moved by hand.
RGB LED strip: select a color and click "Send Color"; click "Turn Off" to switch it off.
Buzzer: click "Short Beep / Double Beep / Long Beep" to test.
5.5 Record and Replay Data
Record: click [Record Data] at the top to start, and click again to finish; the data is saved as a
.csvfile.
Replay: click [Import Replay] and select a previously recorded
.csvfile; you can pause, drag the progress, and adjust the speed. The device cannot be controlled during replay, and the serial port must be reconnected after replay ends.
6. Magnetometer Calibration
This step is only required when using a v4.0 single-ROS control board; on a car, motor currents affect the calibration, so errors will remain after calibration
When is calibration needed?
When using a single-ROS control board;
When the board has been moved to a different mounting position, or the surrounding magnetic environment has changed (motors, metal brackets, etc. installed).
Before calibrating:
Turn off the motors and stay away from large metal objects, magnets, high-current cables, phones, and speakers;
Keep the serial connection normal with data flowing.
Step 1: Enter the Calibration Workbench
Click 06 Calibration Workbench on the left.
Step 2: Understand the Demonstration
At the top of the page there is an animation demonstrating how to hold the board and trace a "figure 8" in the air while flipping and tilting it. All orientations (front, back, and every direction) must be covered.
Step 3: Start Calibration
Click [▶ Start Official Calibration].
Hold the board and, following the demonstration, trace figure 8s slowly and steadily in the air while continuously flipping and tilting it.
Watch the "Calibration Accuracy" level rise from 0 to 3, and the "Calibration Passed" prompt appear.
Step 4: Save
After "Passed" appears, stop rotating.
Before the countdown ends, click [💾 Save and Verify].
Wait for the "Saved and verified successfully" prompt.
Step 5: ⚠️ Restart the Board (Required)
After saving, while the board is stationary, you must press the RESET button on the board, or power it off and on again, for the new parameters to take effect.
Step 6: Verify the Result
After resetting, wait for the control board to beep once.
Click "Read Flash" and confirm that the status shows "Calibrated".
Switch to [Magnetic Data Observation] and slowly rotate the board in place:
The X / Y / Z curves change with the orientation;
The total magnetic field |B| curve should be basically flat; the smaller the fluctuation (CV value), the better.
7. Language and Background Switching
Language menu in the upper-right corner: switch between Chinese / English instantly without disconnecting the device.
Background: choose Dark or Light; the software remembers your choice.
8. Proper Exit
Click [Disconnect Serial Port] in the upper-right corner.
Click the × in the upper-right corner of the window to close it.
9. FAQ
| Symptom | Cause | Solution |
|---|---|---|
| No board in the list after clicking Connect | The cable is charge-only / not plugged in firmly / driver missing | Try another data cable or a different USB port; open Device Manager and check for "Ports (COM)"; if the driver is missing, install the CH340 / CP210x driver |
| Prompt saying the serial port failed to open / is in use | Another program is occupying the serial port | Close serial assistants, the Arduino/VS Code serial monitor, etc. |
| Connected but FPS is 0 and there is no data | The board is not powered / wrong firmware / wrong baud rate | Check the power switch; confirm the matching firmware is flashed; the baud rate should be 115200 |
| The 3D model direction is opposite to the real device | Different mounting orientation | Check R / P / Y under "Flip 180°" |
| Still shows "Uncalibrated" after saving the calibration | The board was not restarted after saving | Press RESET on the board or power it off and on again |
| Cannot find the window after minimizing it | The program is running in the system tray | Double-click the tray icon or double-click the EXE again |
| Double-clicking the EXE does nothing / it will not open | .NET 4.5+ or a browser is missing, or it is blocked by antivirus | Install Edge / Chrome; add the program to the antivirus whitelist; obtain the complete archive again |
| Prompt saying the browser does not support serial ports | An unsupported browser is being used | Open it through the EXE; Edge / Chrome must be installed on the system |
10. Contact After-Sales Support
If you encounter a problem you cannot solve:
Click "Help / About" in the lower-left corner → "Export Fault Report" and save the JSON file;
Send that file, a description of the problem (what you did and what happened), and screenshots to the after-sales staff.