Welcome to RDK S100(P) Board repository
2.2 Remote Login
Remote Login
Remote Login0.Default Login Accounts1.Serial Login2.Network Status Verification3.Enabling the VNC Service4.VNC Login5.SSH LoginTerminal SoftwareCommand Line
This section introduces how to remotely access the development board from a personal computer (PC) via serial port or network (SSH&VNC).
0.Default Login Accounts
The RDK S100(P) system provides two default accounts for first-time users:
- Standard user: Username
sunrise, passwordsunrise - Superuser (root): Username
root, passwordroot
Before logging in remotely over the network, ensure the development board is connected to the network via wired Ethernet or wireless Wi-Fi, and that its IP address has been properly configured. For IP address information under both connection methods, refer to the descriptions below:
Wired Ethernet:
- The development board’s eth1 interface uses a static IP by default: IP address
192.168.127.10, subnet mask255.255.255.0, gateway192.168.127.1. - The eth0 interface uses DHCP by default; its IP address is typically assigned by the router. You can check the eth0 IP address via the
ifconfigcommand in the device’s command line.
- The development board’s eth1 interface uses a static IP by default: IP address
Wireless Wi-Fi: The development board’s IP address is usually assigned by the router. You can check the wlan0 IP address using the
ifconfigcommand in the device’s command line.
1.Serial Login
Before logging in via serial, ensure the development board’s serial cable is correctly connected to your PC.

Serial login requires a PC terminal tool. Commonly used tools include Putty, MobaXterm, etc. Users can choose based on personal preference. The port configuration process is similar across different tools. Below, we use MobaXterm as an example to illustrate creating a new serial connection:
- When the USB-to-serial adapter is plugged into the PC for the first time, install the serial driver. After installation, the Device Manager should correctly recognize the serial port, as shown below:

Open
MobaXterm, clickSession, then selectSerial.Configure the port number (e.g.,
COM11). Use the actual COM port recognized by your PC.Set the serial port parameters as follows:
Parameter Value Baud rate 921600 Data bits 8 Parity None Stop bits 1 Flow Control None


Press Enter to activate login. Enter username: root Password: root Log in

At this point, you can use the ifconfig command to check the development board’s IP addresses. Interfaces eth0/eth1 and wlan0 represent wired and wireless networks, respectively:
xeth0: flags=4099<UP,BROADCAST,MULTICAST> mtu 1500 ether c8:30:76:63:2d:93 txqueuelen 1000 (Ethernet) RX packets 7547 bytes 2230733 (2.2 MB) RX errors 0 dropped 2 overruns 0 frame 0 TX packets 1126 bytes 108615 (108.6 KB) TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0 device interrupt 93eth1: flags=4163<UP,BROADCAST,RUNNING,MULTICAST> mtu 1500 inet 192.168.127.10 netmask 255.255.255.0 broadcast 192.168.127.255 inet6 fe80::e0b2:71ff:fea0:6ba7 prefixlen 64 scopeid 0x20<link> ether e2:b2:71:a0:6b:a7 txqueuelen 1000 (Ethernet) RX packets 43 bytes 3882 (3.8 KB) RX errors 0 dropped 1 overruns 0 frame 0 TX packets 46 bytes 6234 (6.2 KB) TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0 device interrupt 99lo: flags=73<UP,LOOPBACK,RUNNING> mtu 65536 inet 127.0.0.1 netmask 255.0.0.0 inet6 ::1 prefixlen 128 scopeid 0x10<host> loop txqueuelen 1000 (Local Loopback) RX packets 46 bytes 6342 (6.3 KB) RX errors 0 dropped 0 overruns 0 frame 0 TX packets 46 bytes 6342 (6.3 KB) TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0wlan0: flags=4099<UP,BROADCAST,MULTICAST> mtu 1500 ether 28:d0:43:83:63:57 txqueuelen 1000 (Ethernet) RX packets 0 bytes 0 (0.0 B) RX errors 0 dropped 0 overruns 0 frame 0 TX packets 0 bytes 0 (0.0 B) TX errors 0 dropped 0 overruns 0 carrier 0 collisions 02.Network Status Verification
Before remote login, ensure network communication between your PC and the development board is functional. If you cannot ping the board, follow these steps to verify:
- Confirm that the IP addresses of both the development board and PC share the same first three octets (e.g., board:
192.168.127.10, PC:192.168.127.100). - Verify that subnet masks and gateway configurations match on both devices.
- Ensure the PC’s firewall is disabled.
The outer Ethernet port (eth1) on the development board uses a static IP by default: 192.168.127.10. For direct connection between the board and PC, configure the PC with a static IP in the same subnet. On Windows 10, follow these steps to set a static IP:
- In Network Connections, locate and double-click the relevant Ethernet adapter.
- Double-click "Internet Protocol Version 4 (TCP/IPv4)".
- Enter the network parameters in the fields highlighted in red below, then click OK.

To configure the development board’s wired network to use DHCP instead, refer to the [2.1 Network Configuration]
3.Enabling the VNC Service
Locate the RDK Configuration item in the menu bar and click to open it.

Select Interface Options -> VNC, and follow the prompts to enable or disable the VNC service. When enabling VNC, you will need to set a login password. The password must be an 8-character string consisting of numbers and letters.

4.VNC Login
This section is for users of the Ubuntu Desktop system and describes how to log in remotely using VNC Viewer. VNC Viewer is a graphical desktop sharing software that allows you to remotely log in to and control the desktop of a device from your computer. This software allows you to view the development board's system desktop on your computer monitor and use your computer's mouse and keyboard for remote operation.
- Open
VNC Viewer, enter the development board's IP address, enter the VNC login password you set in the previous section [Enabling VNC Service], and click OK to log in.


5.SSH Login
Terminal Software
In addition to logging in to the remote desktop via VNC, you can also log in to the development board via SSH. Below, we will use MobaXterm as an example to illustrate the process of creating a new SSH connection:
Open
MobaXterm, clickSession, then selectSSH.Enter the development board’s IP address (e.g.,
192.168.2.112).Check
specify usernameand entersunrise.Click OK, then enter the username (
sunrise) and password (sunrise) to log in.

Command Line
You can also log in via SSH from the command line:
- Open a terminal window and enter the SSH command, e.g.,
ssh sunrise@192.168.2.112. - When prompted to confirm the connection, type
YES. - Enter the password (