Welcome to K230 Vision Module repository
9. stm32_k230 human body detection
stm32_k230 human body detection
stm32_k230 human body detectionk230 and stm32 communication1. Experimental Prerequisites2. Experimental wiring3. Main code explanation4. Experimental Phenomenon
k230 and stm32 communication
1. Experimental Prerequisites
This tutorial uses the STM32F103C8T6 development board, and the corresponding routine path is [14.export\STM32-K230\09_STM32_k230_person_detect].
K230 needs to run the [14.export\CanmvIDE-K230\09.person_detection.py] program to start the experiment. It is recommended to download it as an offline program.
Things you need:
Windows computer, STM32F103C8T6 development board, USB to TTL module, K230 visual module (including TF card with burned image), Type-C data cable, connection cable (Dupont cable)
2. Experimental wiring
| k230 vision module | STM32 |
|---|---|
| 5V | VCC |
| GND | GND |
| TXD(IO9) | PA3 |
| RXD(IO10) | PA2 |
| USB to TTL module | STM32 |
|---|---|
| RxD | PA9 |
| TXD | PA10 |
| GND | GND |

3. Main code explanation
void Pto_Data_Parse(uint8_t *data_buf, uint8_t num){ uint8_t pto_head = data_buf[0]; uint8_t pto_tail = data_buf[num-1]; if (!(pto_head == PTO_HEAD && pto_tail == PTO_TAIL)) { printf("pto error:pto_head=0x%02x , pto_tail=0x%02x\n", pto_head, pto_tail); return; } uint8_t data_index = 1; uint8_t field_index[PTO_BUF_LEN_MAX] = {0}; int i = 0; int values[PTO_BUF_LEN_MAX] = {0}; for (i = 1; i < num-1; i++) { if (data_buf[i] == ',') { data_buf[i] = 0; field_index[data_index] = i; data_index++; } } for (i = 0; i < data_index; i++) { values[i] = Pto_Char_To_Int((char*)data_buf+field_index[i]+1); } uint8_t pto_len = values[0]; if (pto_len != num) { printf("pto_len error:%d , data_len:%d\n", pto_len, num); return; } uint8_t pto_id = values[1]; if (pto_id != PTO_FUNC_ID) { printf("pto_id error:%d, func_id:%d\n", pto_id, PTO_FUNC_ID); return; } int x = values[2]; int y = values[3]; int w = values[4]; int h = values[5]; printf("person:x:%d, y:%d, w:%d, h:%d\n", x, y, w, h);}The above functions are for parsing K230 data. Only when they meet specific protocols can the corresponding data be parsed.
in
- x: is the horizontal coordinate of the upper left corner of the recognized box
- y: is the vertical coordinate of the upper left corner of the recognized box
- w: is the width of the recognized frame
- h: is the length of the recognized frame
4. Experimental Phenomenon
- After connecting the cables, the k230 visual module runs offline. After K230 is connected to Canmv IDE, open the corresponding program, click [Save open script to CanMV board (as main.py)] on the toolbar, and then restart K230.

- The hex file generated by the STM32 burning routine.

The serial port assistant is set to the interface shown in the figure

When the K230 camera recognizes a human body, the serial port assistant will print out the information transmitted from k230 to stm32.
in
x: is the horizontal coordinate of the upper left corner of the recognized box
y: is the vertical coordinate of the upper left corner of the recognized box
w: is the width of the recognized frame
h: is the length of the recognized frame
As shown in the figure below